Toggle Comment visibility. how do you power the lynx 5v line? Mechanical connections 6.1.1. Fitted a Midi fuse in a Victron Lynx Distributor. Is it OK? Our phone line is currently unavailable. I am very sure I dont have + and - reversed though. This feature is not available when connected to a Lynx Shunt VE.Can. Be the first to review Victron Lynx Distributor. Victron Lynx Distributor fuses too large? Victron Lynx Distributor - GWOFFGRID It offers a compact all-in-one solution for connecting various sub-systems in your electrical system (e.g. 1 Answer 48V Megafuse vs T-fuse for lithium batteries? Potentially 6 if you count the additional DC DC charger we would like to add. Therefore, we cannot be responsible for the protection and privacy of any information which you provide whilst visiting such sites and such sites are not governed by this privacy statement. The other three fused spaces are taken up by the Multiplus and two . Our ABN is 26082231892. The Distributor is made to hold Mega fuses, but unfortunately they're not available in amperages below 125A, at least not rated for 48 Volt systems. DC Distribution systems & Fuses - Victron Energy Safety Warnings Lynx Distribution System, 3.1. The Lynx Distributor contains a positive and a negative busbar. For all DC connections the following applies: All cables and wires connected to the Lynx module need to have been fitted with M8 cable lugs. Grid Interactive and Inspection Approved 48V System, Solar Friendly Heat Pump Air Conditioners. The ground connection of the Lynx Distributor has a wire with red cable lug already connected to it. The fuse needs to be rated at 1.25 x the total current of both chargers. If the fuse name is empty (0 characters), the fuse will be disabled from monitoring and be ignored. For a better experience, please enable JavaScript in your browser before proceeding. For more information see the Fuses and fuse holders product page. Mike Dorsett already explained this, but I will give you an example. Thanks Seb71. A selection of MEGA fuses with a variety of current ratings. You can choose to accept or decline cookies. Field test: PV Modules. The inputs and outputs on the positive side of the Orions are protected with fuses of 60A each. The RJ10 connection is not protected against reverse polarity. Hi there, very first question out here, hoping someone can help We are planning to use one lynx distributor (probably with a smart shunt), but are wondering if that's possible with our intended setup? Suggested alternatives: Alvolta 250A Red Busbar Alvolta 700A Red Busbar Incl Cover The Lynx Distributor is designed to hold MEGA fuses. Victron Lynx Distributor. As you have discovered, 100A is the lowest rating in the 58V Mega fuse range. Since each solar charger is able to produce 60A (assuming you also have enough PV panels), you have a current of up to 120A into that fuse. Nov 04 2019 at 11:17 PM Hi Peter Please take a look at https://www.victronenergy.com/blog/2019/09/03/wiring-unlimited/ Fuse size is typically related to the cable diameter, it protects against a condition where the cable heats up enough to cause a fire. On the other hand, you don't want the fuse to blow at normal current values. It's made up of a positive busbar, a negative busbar and four MEGA fuse holders. It is subject to change without notice. :D, Solar Equipment Reviews and Technical Support. We are very limited in space (and weight) so would prefer not to have to add a second lynx distributor if we can avoid it :-), (oh and sorry admins, I selected the topic 'lynx shunt' as there is nothing suitable to select as lynx or lynx distributor, don't seem to exist as a topic.). Tighten the nuts with a torque moment of 14Nm. MultiPlus 3KW 120VAC 12VDC 400Ah Li VEBus BMS generator MPPT BMV CCGX Orion-Tr Smart Lynx distributor . I work for a distributor and we were having this same issue with one of our larger projects, conveniently for us, Victron sent this out yesterday, so I figured I should share. This is a section of that schematic showing the 2 orions connected together and going to the one fuse on the Lynx. The fuse monitors in Lynx Distributor modules with older firmware (before serial number HQ1909) cannot detect a blown fuse when batteries are connected. Description. The Victron Lynx Distributor is a modular busbar and fuse holder system and is the perfect way to distribute overcurrent-protected power to all of your high amperage DC devices like an Inverter/Charger, Solar Charge Controller, DC DC Charger, or 12V Fuse Block. solar arrays, inverters, B2B chargers) to your leisure batteries. However, once you have used these links to leave our site, you should note that we do not have any control over that other website. The Lynx Distributor communicates operational status and the status of each fuse via the RJ10 cable to a Lynx Smart BMS. I guess I could live with the knowledge that LED OFF = OK, but still it's a bit weird and doesn't feel right. A modular DC bus bar, used to connect batteries to the Lynx DC distribution system. I have tested all the new fuses just via continuity test and the batteries are getting charged. Everything is working. Much appreciated! It might be something with the resistance in the fuse to do. On the settings page scroll down to the Lynx Distributor settings. Cookies allow web applications to respond to you as an individual. Is it ok to have those going to the same stud? We may change this policy from time to time by updating this page. Jul 16 2020 at 7:26 PM That's alot of cables into one small set of bus bars, use a lynx power in, they're the distributor minus the useless fuse indicator pcb, and therefore half the price. To connect to another Lynx Distributor, feed the cable through its bottom recess and plug the RJ10 cable into the RJ10 connector. All the components have shutoff switches in between them. We may use the information to improve our products and services. Welcome to our website. There are only five of the eight fuses being use. It is part of the Lynx Distribution system. I never thought of that. As well as the option to use a small busbar and connect that to the one position on the lynx. The problem is I need a 30amp fuse which Mega fuses don't come in of course. I have replaces the Lynx Shunt 1000 to see if this made a difference, but still the same thing happens. Think multiple 12 AWG wires, fused with a holder or in-line fuse outside the Lynx? System example - Lynx Smart BMS, 2x Lynx Distributor and lithium batteries, 5.1.5. By the time I get two good quality bus bars of similar capacity, add in fuse holders, jumper cables, fuses, and all the other bits, Im pretty much at the same price. | Please allow 1-3 business days for processing. Technical specifications Lynx Distributor, chapter 6.1.3. Lynx Distributor Red LED - But Fuse Not Blown. - Victron Community BusbarsVictron Lynx Distributor or just the Victron Lynx Power In? thanks so much!!! In order to prevent unauthorised access or disclosure, we have put in place suitable physical, electronic and managerial procedures to safeguard and secure the information we collect online. 24v system with 3 Quattros. is it an isolated source? Add to cart. If the Lynx Distributor is connected to a Lynx Smart BMS it can be monitored and setup with the VictronConnect App. Perc: 9471 kWh I have raised this with my retailer (CR for multiplus, and another company for the lynx) and they stated they would open a ticket with Victron, but have heard anything. The negative busbar has four connections and a ground connection. There are two RJ10 connectors in each Lynx Distributor, one on the left and one on the right. Up to 4 Lynx Distributors can be connected to a Lynx Smart BMS. These links are provided for your convenience to provide further information. Before placing fuses, first check if the bottom nuts of the middle row are tightened correctly to a use torque moment 10Nm. You acknowledge that such information and materials may contain inaccuracies or errors and we expressly exclude liability for any such inaccuracies or errors to the fullest extent permitted by law. The Lynx Distributors communicate fuse status and operational status to the Lynx Smart BMS. I have a Lynx distributor. Once you agree, the file is added and the cookie helps analyse web traffic or lets you know when you visit a particular site. There should only be one ground connection per system. A real world comparison between Mono, Poly, PERC and Dual PV Modules. Fuses & fuse holders - Victron Energy Connecting the positive wires Lynx Distributor. I also have this issue when charging off the multiplus ii 3000/12. Recommendation on an appropriate fuse size? I have found a schematic on the Victron website (US-VAN-Drawing-VEBus-BMS-MultiPlus-3KW-DMC-400Ah-Li-Cerbo-SBP-100A-&-65A-SmartShunt-MPPT-100-50-OrionTr.pdf) which seems to agree with you as it has 2 Orions connecting to the one fuse on the Lynx distributor. MRBF fuse in Lynx Distributor at 48V? - Victron Community I feed it with 5V with the RJ connector. I will make some small changes in my diagram and think I will then be sorted with using the Lynx. De Paal 35 Oh good question - the lynx tech specs say 60V. Your email address will not be published. I am really running out of ideas as this is a weird one. This material includes, but is not limited to, the design, layout, look, appearance and graphics. Hi all, me again :) I am thinking of using the Lynx Distributor to put my battery, the Multiplus II and my MPPT 100/20s in parallel. The system will limit 100A through the cables, but a short would potentially put too much current through the cables. The Victron Lynx Distributor is a modular busbar and fuse holder system and is the perfect way to distribute overcurrent-protected DC power. Any suggestion? Name the Lynx Distributors from left to right: A, B, C and D. Do this so that the fuse alarms correspond with the Lynx Distributor names. Hello, Hoping I can get some help here, I am installing 2 new Multiplus-II in parallel system and all seems to be working well except i get all LED lights as red on the lynx distributor when I have AC power on and the inverters are charging. Find a dealer Ive been pricing this out, and the Lynx bus bars are remarkably cost competitive. Is there any way you could make another one if I paid you? When the Quattros are under heavy load - the fuse lights go red. But you have the second condition: the fuse used to protect that wire. It can only detect a blown fuse if loads are connected. But when I install the 24V battery all the LEDs light up red. 254.02 213.89 Add to cart Description Specification Reviews (0) Datasheets Victron Energy Lynx Distributor - LYN060102000 The Victron Lynx Distributor contains a positive and negative busbar and provides a connection for 4 individual DC equipment circuits, loads or DC groups. So you will have to use a 150A fuse or so. Seplos Mason 48 volt 135 AH DIY kit - Build and operation report, Another panel install, thought to share my experience. Have a Question About This Product? While typing a post to find a similar solution I came across your thread. VICTRON DC Distribution systems & Fuses - Energy Eco In short, this is a cosmetic issue I believe. VictronConnect App Learn more SKU: LYN060102000 Categories: Best Sellers, DC Distribution & Fuses, Victron Description Features Specs Docs Reviews (0) Description A modular DC bus bar, with locations for four DC fuses. WE CAN CREATE YOU A CUSTOMISED SYSTEM, PLEASE CONTACT US. I am a real newbie to all things electrical so am still reading all the manuals and am trying not to get too confused with all the different options to try to see if I can work out the components that would work best for us :-) Victron does seem to indicate with their drawing that it is perfectly fine to link 2 Orions into the one fuse on the Lynx distributor in their schematic, so I am really hoping the MPPTs fall into the same category Then I would only need the 4 fuses on the Lynx (1 for the DC loads, 1 for the inverter, 1 for the 2 MPPTs and 1 for the 2 Orions). Is there a specific reason why you don't recommend it that I am missing? We will promptly correct any information found to be incorrect. When a fuse blows, the red fuse LED will illuminate, the power LED will turn red and an alarm message is send to a connected Lynx Smart BMS. That is enormously helpful! These need to be purchased separately. Building the electrical system for a camper van, based around 2x 300Ah Lifeblue lithium batteries in parallel, and we're looking at the possibility of using the Lynx Distributor to combine these batteries (by itsself, no lynx shunt or power-in). Victron Lynx Distributor fuses too large? : r/Victron - Reddit Leave this wire in place when connecting the ground wire. Im actually thinking of connecting all my strings into a lynx power in. We use traffic log cookies to identify which pages are being used. It shall be your own responsibility to ensure that any products, services or information available through this website meet your specific requirements. This means you must size the fuse for 120A. Not up for DIY? Lynx Shunt VE.Can - A positive busbar with a space for a main system fuse and a negative busbar with a shunt for battery monitoring. See below drawing. We are having the same issue. Amazon.com: Victron Energy Lynx Distributor : Automotive Help, my SmartLithium doesn't allow me to discharge, says voltage is too low. Toggle Comment visibility. The Lynx Distributor is a more compact and cost-effective solution than using individual busbars and external fuses. This chapter might not apply if the Lynx module is connected to other Lynx modules, like can be the case for the Lynx Smart BMS or the Lynx Shunt VE.Can. Technical specifications Lynx Distributor. Attachments: Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total. Battery Switch 275 A. . Pay attention to the correct placement of the cable lug, washer, spring washer and nut on each bolt when attaching the cable to the bolt. Only way fuses work is to have a limited sized conductor that will self destruct, as a result it needs to have some resistance at higher loads. The Victron Lynx Distributor is a modular busbar and fuse holder system and is the perfect way to distribute overcurrent-protected power to all of your high amperage DC devices like an Inverter/Charger, Solar Charge Controller, DC DC Charger, or 12V Fuse Block. Might i need to make my own BB instead? The term Outback Marine Australia Pty Ltd or us or we refers to the owner of the website whose registered office is . May 04 2021 at 1:56 AM I am in a similar predicament. Additional resources still need to be added for this topic, Fuse needed for the MPII 5000/48V and Pylontech batteries, Multiplus II GX wiring to generator (AC-in), Multiplus 2, load the Battery function not needed. Im trying to wrap my head around best way to do this.. any advice/input appreciated. thanks, Wire Size Chart: Allowable Ampacities of Conductors in Free Air - 30C. See below table how to set the DIP switches for each unit. Same here, but all systems are working correctly Would be nice to hear from Victron. My distributor has all 5 lights red. Amazon.com: Victron Lynx Distributor Fuse It will monitor the status of each fuse, and indicate its condition with a LED on the front. Victron Lynx Distributor | Caravan Battery & Electrical - My Generator 1351 JG Almere #1 I've found a workaround to fit Midi fuses into a Lynx Distributor, but I haven't energised it yet. If I unplug and replug the RJ11 cable then the green power light comes on, all fuse LEDs go green, then back to red again. How to Add Fuse Holders to a Victron Lynx Power In for a DIY Camper Current Visibility: Viewable by moderators and the original poster. . So do not count those when comparing prices. Mono: 9158 kWh 1 of 3 - Explanation of Victron Energy Lynx Distributor & Power In. Leave this wire in place and place the fuse on top of the red cable lug. A cookie in no way gives us access to your computer or any information about you, other than the data you choose to share with us. They would definitely fit in the outside holes! Only thing I cna think might be to use 2x the connections to multiplus or we stop doing giant 12v systems. Find a Victron Energy dealer near you. Lynx Shunt VE.Can. If connected to a Lynx Smart BMS, up to 4 Lynx Distributors can send fuse status information to the Lynx Smart BMS. Restrictions: The wire from the fuse to each unit should be able to handle the full current of the fuse rating. It will monitor the status of each fuse, and . Had the same thing happen on a customer install this week. Internal parts and wiring diagram Lynx Distributor, 1.1. This feature is not available when connected to a Lynx Shunt VE.Can. The Victron Lynx Distributor is a modular busbar and fuse holder system and is the perfect way to distribute overcurrent-protected DC power. Each solar charger can charge with 60A, so from this condition the wire should be able to safely carry 60A. Power Distribution Victron Lynx DC Distribution System Victron Lynx Distributor Victron Lynx Distributor A modular DC busbar, with locations for four DC fuses. We arecommitted to ensuring that your privacy is protected. Additional resources still need to be added for this topic, No LED on Lynx shunt and distributor yet power is going through to system, Lynx Shunts sometimes not showing on Cerbo. Help with switching simple 12v marine system from PWM to MPPT. Place all 4 fuses, even if not all 4 circuits are used. Update - Even in standalone when the lynx distributor is under load the lights turn red. Answer to both questions is yes you can (connect 2 sources / loads to one fuse) and no they don't (have to be the same rating). Cant find anyone who can tell me if the lynx power in can do the 200 plus volts though. Balmar XT Series Charging Systems for Mercedes Sprinter, Victron Multi RS Solar Hybrid Inverter/Charger, Victron Phoenix Smart Inverter 1600VA - 5000VA, Victron Phoenix Smart IP43 Battery Chargers, Drop In Replacement 12V/24V Lithium Batteries, Enerdrive Lithium Batteries eLITE and ePOWER B-Tec, Deka Intimidator - Dual Purpose AGM Batteries, Low Voltage Disconnectors / Battery Protects, Raymarine Evolution System Packs With Drives, Mobile Phone Signal Boosters / Cellular Repeaters, Caravan / RV Mobile Phone Signal Boosters, Home / Building Mobile Phone Signal Boosters. Lynx Distributor. Within 30 days. if you have previously agreed to us using your personal information for direct marketing purposes, you may change your mind at any time by writing to or emailing us. I'm having a similar but slightly different issue: the lights that should be green are OFF when a (working) fuse is connected. Up to 4 connected Lynx Distributors can be monitored with a GX device if they are connected to a Lynx Smart BMS. (contiguous USA) Dismiss. Victron Lynx Distributor - do you need one in your electrical system? This means you size wires to safely carry currents up to the point at which the fuse will blow.

Indeed Mortgage Underwriter, Articles F

fuses for victron lynx distributor